Feature: ItemTechnical SpecificationsOutputDC voltage12V24V36V48V60V (This item) Rated current 33.3A 16.6A 11.1A 8.3A 6.6AR ated power 399.6W 398.4W 399.6W 398.4W 396WRipple and noise; ? <150mV;;<150mV<240mV<240mV<240mVVoltage accuracy±1%Output voltage adjustment range±10%Load Regulation<±1.2%<±1%<±0.5%<±0.5%<±0.5%Linear adjustment rate<±1%InputVoltage range90-132VAC/180-264VAC 47Hz~63Hz;;254VDC~370VDC
Efficiency (typical) ?> 82%>84%>86%>86%>86%Working current <5.2A 115VAC,;<2.8A 230VAC
Electric shock110VAC:;25A, 220VAC:;50AStart, rise, hold time200ms, 50ms, 20ms: 230VAC
ProtectionOverload protection105%-135% type: constant current output, +V0 falls to undervoltage point to cut off output, reset: power on againOvervoltage protectionTurn off output when > =115%-145%Undervoltage protectionTurn off output when <10%-45%Short circuit protectionClose output;Over temperature protectionRTH3:> =65°C fan starts, <=55°C fan off, > =80°C off output (5V-15V)
RTH3: >=70°C fan starts, <=60°C fan off, > =85°C off output (18V-48V)EnvironmentWorking temperature, humidity-10°C ~+50°C,; 20%; ~90%RHStorage temperature, humidity-20°C ~+85°C, 10%~95%RHSafetyWithstand
voltageInput-Output: 1.5KVAC;
Input - Enclosure: 1.5KVAC;
Output - Enclosure: 0.5KVAC for 1 minuteLeakage currentInput-output <6mA at 1.5KVACL eakage currentInput-output < 1.5 mA at 220VAC
Isolation resistanceInput-output, input-housing,;
output-housing: 500VDC/100MOOtherSize215*115*50mmNet reset / gross reset 874.1 / 936.3 g ?Ripple and noise measurement method: Use a 12mm twisted pair cable, and the terminal should be connected with 0.1 uF and 47uF capacitors in parallel and measure at 20MHz bandwidth. ?Efficiency is tested at an input voltage of 230VAC, rated load, and ambient temperature of 25°C.
Accuracy: Includes setting error, linear adjustment rate and load adjustment rate.
Linear Rate Test Method: Test from low voltage to high voltage at rated load.
Load regulation test method: from 0% to 100% of rated load. The startup time is measured in the cold start state. The fast and frequent switching machine may increase the startup time. When the operating altitude is higher than 2000M, the operating environment temperature should be reduced by 5°C/1000M.
Package includes: 1 x
Power Supply;
Note: Due to logistics reasons, the following problems may occur after you receive the goods (just like the picture), you can use your hand to adjust, that's ok, if you mind this, please stop buying.;