Buy APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3' in United States - Cartnear.com

APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3'

CTNR1409815 0731304331650 CTNR1409815

APC

APC
2025-11-24 USD 1586.81

$ 1,586.81 $ 1,619.19

Item Added to Cart

*Product availability is subject to suppliers inventory

APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3'
SHIPPING ALL OVER UNITED STATES
APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3'
100% MONEY BACK GUARANTEE
APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3'
EASY 30 DAYSRETURNS & REFUNDS
APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3'
24/7 CUSTOMER SUPPORT
APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3'
TRUSTED AND SAFE WEBSITE
APC / Schneider Electric - AP7968B - APC by Schneider Electric Rack PDU,Switched,ZeroU,12.5kW,208V,(21)C13&(3)C19;3'
100% SECURE CHECKOUT
Brand APC
Model AP7968B
Type Switched
Rack Size 0U
Style Vertical
Certifications cUL Listed, CSA, FCC Part 15 Class A, ICES-003, Industry Canada, UL 60950, UL Listed
ROHS Yes
Input Voltage 208V 3PH
Input Frequency 50/60 Hz
Maximum Input Current 35A
Cord Length 3.0 Feet
Output Voltage 208V
Output Connector(s) 21 x IEC 320 C13 (Battery Backup) 3 x IEC 320 C19 (Battery Backup)
Operating Environment -5 - 45 Degree Celcius
Operating Relative Humidity 5 - 95%
Operating Elevation 0 - 3000 m
Storage Temperature -25 - 65 Degree Celcius
Storage Relative Humidity 5 - 95%
Storage Elevation 0 - 15000 m
Features Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Dimensions 2.20" x 3.50" x 70.00"
Weight 17.78 lbs.
Package Includes Rack PDU, Cord Retention Bracket(s), Documentation CD, Installation Guide, Rack Mounting Brackets, RS-232 configuration cable, Toolless Mounting Kit
Explore APC Rack Power Distribution in 3D animation. APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power cycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing time delays allow users to define the order in which to power up or down attached equipment to avoid circuit overload. Current metering provides real-time remote monitoring of connected loads with user-defined alarms to warn of potential circuit overloads. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, Command Line Interface, or Telnet Interfaces which are complimented by APC Centralized Management platforms using StruxureWare Data Center Expert, Operations, Capacity, and Energy Efficiency.

...
Protection Type: Overload
ProtectionOutput Voltage: 208
V ACInput Current: 35
APlacement: RackRack
Height:
0UHeight:
70Width: 2.2"D
epth: 3.5"W
eight (Approximate): 17.78 lb"