Specifications:;
Timing range: 0-999s
0-999m 0-999hSupply voltage: DC12V
/AC110V-220VRelay: 20AWorking
current: 10A (max)
Power: 500W (max)
Size: 79*26*43mmHole
size: 72*40mm;
Instructions:; Please pay attention for your first use. You need wait 6s after your setting data, the module will save the date you have set after 6s.;; Short press button
SET: If you start the time setting mode, Nixie tube will blink. You could adjust the time T1 and T2 by button+ and button-. Please wait 5s after your setting date, the module will save the date you have set after 5s.; Long press button
SET: if you start the parameter setting mode. There are two group parameter for your choice;: P0 and P1. You could switch P0 or P1 by short press SET. Under the parameter P0 and P1, you could set the timing mode by the button+ and button-.;
P0--0: Timing
time mode: 0---999s.
P0--1: Timing
time mode: 0---999min.
P0--2: Timing
time mode: 0---999h.
P1--0: The relay will connect after you delay the T1 time.
P1--1: The relay will disconnect after you delay the T1 time.
P1--2: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time, it finish.
P1--3: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time, it finish.
P1--4: The relay will connect after you delay the T1 time; first, Then the relay will disconnect after you delay the T2 time, it is cyclic.
P1--5: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time, it cyclic.
Example: A customer needs 10 seconds to start up and 20 seconds off.
Setup is as follows: T1 set time 10, T2 set time 20P0 -- 0 (T1 time range is seconds) P1--5 (timer work mode);
Package Included:; 1 x Digital Display Time Relay