Buy Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay in United States - Cartnear.com

Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay

CTNR1055420 0799632903567 CTNR1055420

JMT

JMT
2025-11-21 USD 33.63

$ 33.63 $ 33.97

Item Added to Cart

*Product availability is subject to suppliers inventory

Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay
SHIPPING ALL OVER UNITED STATES
Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay
100% MONEY BACK GUARANTEE
Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay
EASY 30 DAYSRETURNS & REFUNDS
Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay
24/7 CUSTOMER SUPPORT
Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay
TRUSTED AND SAFE WEBSITE
Hoymk SSR3-D4810HK 10A DC-AC SSR3 D4810HK 3 Phase Solid State Relay
100% SECURE CHECKOUT
Brand Hoymk
Model SSR3-D4810HK
Type Electronic
Equipment Type Relays
Product Features: 1, TRIAC Output,Zero Voltage Opens, Zero Current Turnoff;2,Input Signal Compatible with TTL and COMS Digital Logic Circuits;3, Optical Isolation between the Input Loop and Output Loop;4,Light Emitting Diode Indicates Working State;5,Dielectric Strength 2500V between Input-Output;6,High Performance, Widely Used, High Reliability of Generic Products7, 100% Load Current Aging Test.Through European Union CE Certification, International ISO9000 Certification, National 3C Certification. Specifications: Control: DC Control AC (DC-AC) Load Current:10ALoad Voltage: 480VAC.660VAC.1200VAC Control Voltage: 3- 32VDCControl Current :10-68mAState Drain Current: 10mAState Buck :1.8VACOff Time: 10mS Dielectric Strength: 2500VAC Insulation Resistance: 1000M/500VDC Work Instructions: LED Weight: 450G Safety Precautions : 1 , Must be Used when the load current is higher than 10A is mounted on a heat sink or metal base plate with the corresponding cooling effect , and coated with thermal grease between the SSR Heat bottom mounting surface , 40A above plus fan forced cooling or water . 2 , Using the AC inductive load , high transient voltages and inrush current is applied to the output, which may cause the solid state relay conduction or damaged, usually require access at the output voltage with a specific clamping voltage control devices, such as double Zener diode or varistor (MOV). Rated voltage varistor is recommended to take a 1.6-1.9 times ; 3, The control close to the minimum load current is small current load shall load a dummy load resistor in parallel to reduce the leakage current compared to the output of the load high residual voltage. 4, In order to avoid the temperature exceeds the allowable value of solid-state relays , considering the cooling effect of the application should be designed and installed position , only when two or more solid state relays mounted side by side , you should leave appropriate spacing. 5 , The parallel between the output may not be more than just the use of solid-state relays , in an attempt to increase the output current. However, output can be used in tandem in order to apply a higher operating voltage. 6, When using more than just a solid state relay when shared control power inputs that can be used in tandem can also be used in parallel . 7 , Capacitive load caution this piece , please select the capacitive load dedicated solid state relays.

Related Products

See More

You May Also Like

See More