Trusted shipping Easy returns Secure shopping

Buy Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output in United States - Cartnear.com

Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output

CTNR1068289 037332182807 CTNR1068289

Tripp Lite

Tripp Lite
2025-12-22 USD 371.06

$ 371.06 $ 374.81 1% Off

Item Added to Cart

*Product availability is subject to suppliers inventory

Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output
SHIPPING ALL OVER UNITED STATES
Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output
100% MONEY BACK GUARANTEE
Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output
EASY 30 DAYSRETURNS & REFUNDS
Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output
24/7 CUSTOMER SUPPORT
Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output
TRUSTED AND SAFE WEBSITE
Tripp Lite - PDUMV30HV2 - Tripp Lite PDU Metered Vertical 5.8kw 208/240V 8 C19 40 C13 L6-30P 0U TAA - Power distribution unit (rack-mountable) - 30 A - AC 208 V - 5.8 kW - input: NEMA L6-30 - output
100% SECURE CHECKOUT
Brand Tripp Lite
Model PDUMV30HV2
Type Metered
Rack Size 0U
Style Vertical
Front Panel LEDs Set of two digital current meters report output current in two segments
Certifications Tested to UL/CAN 60950-1 (USA, Canada), NOM (Mexico), FCC Class A (Emissions), TAA Compliant
ROHS Yes
Input Voltage 200 - 240V
Maximum Input Current 24A
Input Connector(s) NEMA L6-30P
Cord Length 10 ft
Output Voltage 200 V - 240 V nominal, single phase
Output Frequency 50/60Hz
Output Connector(s) 40 x C13; 8 x C19
Overload Protection Set of 2 20A breakers protect output Bank 1 and Bank 2
Operating Environment 0 degrees to 50 degrees C
Operating Relative Humidity 5 - 95%
Operating Elevation 0 - 3000 m
Storage Temperature -15 - 60 degrees C
Features Ideal for server rooms, network closets and data centers Dual load banks with 24 outlets each (4 C19 and 20 C13) Dedicated 20A circuit breakers protect output NEMA L6-30P input plug with 10-ft. (3 m) cord Ready for immediate toolless 0U installation
Dimensions 70.00" x 2.17" x 2.52"
Weight 12.35 lbs.
Package Includes PDUMV30HV2 30A 208/240V 5.8kW Single-Phase Metered PDU Plug-lock inserts (8 C20, 40 C13) Spare installation buttons, 2.9 mm/4.6 mm Ground screw Mounting hardware Owner's Manual
Ideal for server rooms, network closets and data centers Dual load banks with 24 outlets each (4 C19 and 20 C13) Dedicated 20A circuit breakers protect output The 70-inch (178-centimeter) PDUMV30HV2 30A 208/240V 5.8 kW Single-Phase Metered Power Distribution Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers. Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank's real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping.

Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification. An ideal PDU for server rooms, network closets and data centers, the PDUMV30HV2's all-metal housing comes ready to mount vertically in your rack using the preinstalled 9 mm buttons or the included hardware. The NEMA L6-30P input plug with 10-foot (3-meter) cord connects to your facility's compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components' plugs to ensure they remain connected and continuously powered.

Use the included ground screw to connect any equipment that requires a chassis ground. Main Features Ideal for server rooms, network closets and data centers Dual load banks with 24 outlets each (4 C19 and 20 C13) Dedicated 20A circuit breakers protect output NEMA L6-30P input plug with 10-ft. (3 m) cord Ready for immediate toolless 0U installation
General Information Name: Tripp Lite PDU Metered Vertical 5.8 kw 208/240V 8 C19 40 C13 L6-30P 0U TAA, Tripp Lite, Tripp
Lite Category: Tripp Lite, Power, Power Products, Surge Protection & PDUs
UPC Code: 037332182807
Country of origin: Taiwan. Country of origin is subject to change. Detail Specifications OVERVIEW PDU Type Metered OUTPUT Frequency Compatibility 50 / 60 Hz Output Capacity Details 5.8 kW (240V), 5kW (208V), 4.8 kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank 16A max per C19 outlet 12A max per C13 outlet Output Receptacles (40) C13 (8) C19 Output Nominal Voltage Overload Protection Two 20A breakers protect 24 outlets each INPUT PDU Input Voltage Recommended Electrical Service 30A 208/240V Maximum Input Amps 30 Maximum Input Amps Details Agency de-rated to 24A continuous PDU Plug Type NEMA L6-30P Input Phase Single-Phase Input Cord Length (ft. ) 10 USER INTERFACE, ALERTS AND CONTROLS Reported Load Segments Supports local monitoring of output current for each output load bank Outlets, circuit breakers and current meters are color-coded and labeled for easy identification (Black: 20A Bank 1 /
Gray: 20A Bank 2) Front Panel LCD Display Set of two digital current meters report output current in two segments Front Panel LEDs n/a Switches n/a PHYSICAL Form Factors Supported 0u vertical installation in equipment racks, plus under-counter and wallmount Material of Construction Metal PDU Form Factor Vertical (0U) ENVIRONMENTAL Operating Temperature Range 32 to122F (0 to 50C) Storage Temperature Range -30 o C to +60 o C (-22 o F to +140 o F) Relative Humidity 5-95% non-condensing CERTIFICATIONS Certifications Tested to UL/CAN 60950-1 (USA, Canada), NOM (Mexico), FCC Class A (Emissions), ROHS Compliant, TAA Compliant Item Dimension (LxWxH) 7 x 10 x 76 Weight 39 lbs Warranty Information 2-year limited warranty

Related Products

See More

You May Also Like