Tripp Lite Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital meter. Enables visual current monitoring of PDU output current to prevent circuit overloads as additional equipment is added. Offers reliable rackmount multi-outlet power distribution from any protected UPS- generator or mains input power source. High quality design includes rugged all-metal housing and secure rackmount installation with included mounting accessories.
Features
C20 inlet with C20 input cable and L6-20P adapter; 12 ft. / 3.7m line cord
16/20A single phase 200-240V Metered Power Distribution Unit / PDU (Agency de-rated to 16A continuous)
Built-in 2 digit visual meter continuously reports PDU load level in amps
1U horizontal rackmount format installs in one rack space
10 total outlets (8 C13 / 2 C19)
Mounting flanges support installation in 2 and 4 post racks- with additional support for wall-mount and under-counter installation formats
Mounting ears are reversible for front or rear facing rackmount installation
Optional PDUSIDEBRKT enables 0U vertical rackmount in compatible racks
Back panel grounding lugIncludes:
Rackmount PDU
C19 to L6-20P plug adapter
Rack mounting bracketsSpecifications
Digital Load Meter: Yes
Redundant Power Cords: No
SNMP Compatible: No
TAA Compliant: No
Style: Rackmount
PDU Type: Metered
Output Capacity Details: 3.3kW (208V input)- 3.5kW (220V input)- 3.7kW (230V input)- 3.8kW (240V input)- 3.2kW (200V input); 20A maximum (Agency de-rated to 16A continuous)
Frequency Compatibility: 50 / 60 Hz
Output Receptacles: (8) C13; (2) C19
Output Nominal Voltage: 200-240V nominal- single phase
Overload Protection: Outlets are arranged in a single unbreakered load bank
Outlet Quantity / Type: 8 C13 and 2 C19 outlets
Number of Outlets: 10
Outlet Type: IEC-C13- IEC-C19
Customized Load Management Receptacles: Each outlet is individually controllable via remote interface
PDU Input Voltage: 200; 208; 220; 230; 240
Maximum Input Amps: 20
Maximum Input Amps Details: Agency de-rated to 16A continuous
PDU Plug Type: NEMA L6-20P; IEC-320 C20
Input Cord Length (ft.): 12
Input Cord Length (m): 3.7
Material of Construction: Steel
Form Factors Supported: 1U rackmount. Includes mounting accessories for 2-4 post racks
PDU Form Factor: Horizontal (1U- 2U- etc)
Relative Humidity: 0-95% non-condensing
Certifications: Tested to UL 60950-1 (USA- Canada)- Class A (Emissions)- NOM (Mexico)- )- CE (IEC 60950)- (RoHS compliant)
Weight: 6.8 lbs