I. Overview:
HZ210 is a compact frequency meter can measure low-frequency and high-frequency signals.
The module is easy to use, by key operation, select a different testing methods.
Second, the product application:
? measuring the pulse frequency;
? measure radio frequencies;
Third, the technical parameters:
No. Item Parameter Unit Remark
1 measuring low frequency range 1Hz ~ 8MHz Hz
2 low-voltage measurement range of +/- 0.7V ~ +/- 15V
3 measuring low frequency of 1 Hz differentiate
4 measuring high frequency range 2MHz ~ 2.0GHzHz
5 high-frequency voltage measuring range +/- 100mV ~ +/- 5V
6 high-frequency measurement differentiate degrees 1KHZ Hz
7 7 ~ 12 VDC operating voltage
Note: The low frequency signal is not detected AC signal at the input signal terminal series about a 1OuF capacitance measurements.
Measuring the low-frequency signal is a DC-coupled to your own series AC-coupling capacitance measurement.
Fourth, the interface specification and related operations
P1 connector (power supply)
VDD: positive power supply (7 ~ 12V)
GND: power supply negative
P2 Interface (output signal)
FX: measuring low frequency input signal.
RF: measuring the high-frequency input signal.
GND: negative power.
Fourth, Key Description
FUN: Select (high / low frequency) measurement
MODE: Select the display units / counters.
4.1, low frequency measurement
Interface display font:
The first line of "1.FX = 8MHZ"
The second line "00000000Hz"
Key operation:
MODE: Select the display units.
4.2, high-frequency measurements
Interface display font:
The first line of "2.RF = 20.0GHz"
The second line "0000.000MHz"
Key operation:
4.3 cumulative counter (maximum frequency measurement 100KHz)
Interface display font:
The first line of "3.FX = Counter"
The second line "00000000n"
Key operation:
MODE: the counter is cleared.